Clinical Orthopaedics and Related Research: March 2013 - Volume 471 - Issue 3 - p 1000–1007 doi: 10.1007/s11999-012-2613-z Clinical Research

Does A Kinematically Aligned Total Knee Arthroplasty Restore Function Without Failure Regardless of Alignment Category?

Howell, Stephen, M., MD1, 2, a; Howell, Stacey, J., BS3; Kuznik, Kyle, T., BS4; Cohen, Joe5; Hull, Maury, L., PhD1
Knee

Background Kinematically aligned TKA restores function by aligning the femoral and tibial components to the normal or prearthritic joint lines of the knee. However, aligning the components to the joint lines of the normal knee also aligns the tibial component in varus, creating concern that varus alignment might result in poor function and early catastrophic failure.

 

Questions/Purposes We therefore determined whether function and the incidence of catastrophic failure were different when the tibial component, knee, and limb alignment were in a specified normal range, varus outlier, or valgus outlier.

 

Methods We prospectively followed all 198 patients (214 knees) who underwent TKAs between February and October 2008. We treated each knee in this cohort of patients with a kinematically aligned, cruciate-retaining prosthesis implanted using patient-specific guides. From a long-leg scanogram, we measured and categorized alignment of the tibial component as in range (≤ 0°) or a varus outlier (> 0°), alignment of the knee as in range (between −2.5° to −7.4° valgus) or a varus (> −2.5°) or valgus (< −7.4°) outlier, and alignment of the limb as in range (0° ± 3°) or a varus (> 3°) or valgus (< −3°) outlier. We assessed function using the Oxford Knee Score and WOMAC™ score, and reported catastrophic failure as the incidence of revision attributable to loosening, wear, and instability of the femoral or tibial components. The minimum followup was 31 months (mean, 38 months; range, 31-43 months).

 

Results The mean Oxford Knee Score of 43 and WOMAC™ score of 92 were similar between the three alignment categories. The incidence of catastrophic failure in each alignment category was zero.

 

Conclusions Kinematically aligned TKA restores function without catastrophic failure regardless of the alignment category. Because 75% of patients had their tibial component categorized as a varus outlier and also had high function and a zero incidence of catastrophic failure, the concern that kinematic alignment compromises function and places the components at a high risk for catastrophic failure is unfounded and should be of interest to surgeons committed to cutting the tibia perpendicular to the mechanical axis of the tibia.

 

Level of Evidence Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Link to article